Initiative iDose Dosing Pump – 6 LPH
Initiative iDose Dosing Pump – 6 LPH
Couldn't load pickup availability
Compact, Automatic Air-Release Dosing Pump for RO & Water Treatment Systems)
✅ Overview
The Initiative iDose 6 LPH Dosing Pump is a compact and efficient electronic diaphragm pump designed for accurate chemical dosing in RO and water treatment applications. Built with an automatic air-release mechanism, the pump helps prevent gas locking and ensures smooth chemical injection during continuous operation.
Its compact body, stable dosing control, and wide voltage compatibility make it suitable for antiscalant, chlorine, acid, and alkali dosing applications in both commercial and industrial systems.
🫗 Quick Highlights
- Model: iDose V6.5
- Capacity: 6 LPH
- Type: Electronic Diaphragm Dosing Pump
- Feature: Automatic Air Release
- Application: RO & Water Treatment
Share
Suitable for a diverse liquid related applications
Digital Display
Compact and lightweight design

💧 Key Benefits
- Automatic air-release function for smooth dosing
- Stable and accurate chemical injection
- Compact and lightweight body design
- Wide operating voltage compatibility
- Reliable continuous-duty performance
- Easy installation and maintenance
📌 Technical Properties
- Dosing Capacity: 6 LPH Max
- Operating Pressure: 4 Bar
- Stroke Speed: 30–300 strokes/min
- Power Supply: 150–270V AC, Single Phase, 50 Hz
- Power Consumption: 18 Watts
- Discharge / Suction Tube Size: 6 × 12 mm
- Air Release Tube Size: 4 × 6 mm
- Maximum Liquid Viscosity: 50 mPa·s
- Temperature Range: 0°C to 40°C
⚙️ Features
- Automatic air-release system to reduce gas lock issues
- Electronic stroke adjustment for dosing control
- PTFE diaphragm for improved chemical resistance
- Compact weather-resistant body design
- Compatible with common water treatment chemicals
- Stable operation during voltage fluctuations
- Built-in controller with digital stroke adjustment
- Low power consumption with efficient operation
🌊 Applications
- RO antiscalant dosing
- Chlorine / hypo dosing
- pH correction systems
- Water treatment plants
- Commercial & industrial RO systems
📦 In-the-box
- iDose dosing pump
- PVC braided hose
- Air-release hose
- Anti-siphon check valve with duckbill cap
- Foot valve
- Mounting nuts & bolts
- Operation manual
🔧 How To Install
- Choose the Installation Location: Install the dosing pump close to the chemical tank and near the RO feed line. The area should be dry, well-ventilated, and easily accessible for operation and maintenance.
- Mount the Pump Properly: Fix the pump securely on a wall, skid, or base frame. It should remain upright and stable to ensure accurate dosing and long-term reliability.
- Connect the Suction Line: Insert the suction tube into the chemical tank and attach a foot valve with a strainer. Ensure the line is airtight to prevent air entry, which can disturb dosing accuracy.
- Connect the Discharge Line: Connect the discharge tubing to the RO feed pipeline. Install an injection point or non-return valve (NRV) to ensure proper chemical entry and prevent backflow.
- Provide Electrical Connection: Connect the pump to the appropriate power supply as per its rating. Ideally, interlock it with the RO system so the pump runs only when the plant is operating.
- Prime and Start the Pump: Fill the pump head with solution and run it to remove any trapped air. Adjust the dosing rate as required and check all connections before continuous operation.
⚙️ How It Works
Metering Mechanism: A dosing pump operates by delivering a fixed quantity of chemical with each stroke or cycle. This controlled movement allows precise and repeatable dosing, which is essential in RO systems.
Suction and Discharge Process: During operation, the pump first draws chemical from the tank through the suction line, then pushes it into the water line through the discharge side. This alternating action ensures a continuous and steady flow of chemical.
One-Way Flow Control: Internal non-return valves maintain a single direction of flow. This prevents backflow from the pipeline and ensures that each stroke contributes to accurate dosing.
Adjustable Output Control: The dosing rate can be adjusted by changing stroke length, frequency, or speed. This allows the pump to match the exact chemical requirement based on water quality and system design.
Integration with RO System: The pump works in coordination with the RO plant to dose chemicals such as antiscalants, SMBS, or minerals. This ensures membrane protection, proper water chemistry, and consistent system performance.
FREQUENTLY ASKED QUESTIONS
Do you provide installation services?
Yes. We install RO plants, softeners, iron removal filters, ETP/STP systems, and all types of domestic & industrial water treatment plants across India.
Do you offer GST invoices?
Yes. Every order comes with a100% GST-compliant invoice, suitable for dealers, resellers, and industrial use.
How do I know which chemical or filter is suitable for my water?
You can share your raw water report, TDS, or problem description. Our technical team will recommend the correct chemical, membrane, filter media, or system.
Please connect with us from Contact Us.
Can I speak to someone before placing an order?
Yes, you can contact us directly via phone, email, or WhatsApp for product guidance or bulk pricing.